Total Ionic Strength Adjustment Buffer (TISAB II), with CDTA for Fluoride Analysis Using Ion Selective Electrodes
Ready-to-use solutions provide savings in raw materials, labor and waste disposal.
Total Ionic Strength Adjustment Buffer (TISAB II), with CDTA for Fluoride Analysis Using Ion Selective Electrodes
Barang #: 144239335

Total Ionic Strength Adjustment Buffer (TISAB II), with CDTA for Fluoride Analysis Using Ion Selective Electrodes

Barang #: 144239335

IDR 3613064

Price Details

Excluding Shipping & Custom charges ( Shipping and custom charges will be calculated on checkout )

*All items will import from AS

0 ratings Tulis ulasan
Persediaan
AS Diimpor dari toko USA

QTY:

Stok hanya tersisa 6 barang.
Pesan sekarang dan dapatkan kira-kira pada Jumat, Agustus 28
Our Top Logistics Partners
  • fedex
  • dhl
Ready-to-use solutions provide savings in raw materials, labor and waste disposal.
Menampilkan lebih banyak
Garansi U-Care:
Tidak ada
Pilih rencana
fast shipping

Fast
Shipping

free return

Free
Return*

secure packaging

Secure Packaging

100% original products

100% Original Products

pci-dss

PCI DSS Compliance

iso certified

ISO 27001 Certified


paypal payment
visa payment
mastercard payment
american express payment
docu wallet payment
dana payment
bni va payment
bri va payment
danamon va payment
atm permata payment
Note: Step Down Voltage Transformer required for using electronics products of AS store (110-120). Recommended power converters Beli Sekarang.

What Stands Out

Enhanced Accuracy
TISAB II incorporates CDTA, improving the precision of fluoride measurements with ion-selective electrodes, effectively addressing common interference issues faced in conventional testing methods.
User-Friendly
Designed for simplicity, TISAB II allows laboratories and researchers to easily prepare and use the buffer, streamlining the process for consistent and reliable fluoride analysis.
Versatile Application
Ideal for a wide range of analytical environments, TISAB II supports various fluoride testing needs, making it the preferred choice for environmental, clinical, and industrial applications.

Rincian Produk

Shop Total Ionic Strength Adjustment Buffer (TISAB II), with CDTA for Fluoride Analysis Using Ion Selective Electrodes online at a best price in Indonesia. B0043EVKGC
  • Ready-to-use solutions provide savings in raw materials, labor and waste disposal
  • Tight specifications for the most accurate results
  • Minimal lot-to-lot variation improves reproducibility
  • Certified traceable to NIST for regulatory compliance
Item FormLiquid
Volume4 liters
Brand NameRicca Chemical
Unit Count1 Count
ManufacturerRicca Chemical Company
Part Number8670-1
BrandRicca-Chemical
Item Volume4 liters
Item Weight1.5 lbs (680 grams)

Who Should Buy?

Suitable For
  • Laboratory Technicians

    Essential for technicians conducting fluoride analysis using ion selective electrodes in various laboratory environments.

  • Environmental Scientists

    Ideal for scientists assessing water quality and fluoride concentrations in environmental samples and field studies.

  • Academic Researchers

    Beneficial for researchers in academia performing experiments related to fluoride chemistry and ion analysis.

Not Suitable For
  • Home Users

    Not suitable for casual users without specialized knowledge or equipment for fluoride testing at home.

DESKRIPSI PRODUK

Punya Pertanyaan? Berbincanglah dengan kami

Tanya & Jawab Pelanggan

  • pertanyaan: What is TISAB II and how is it used in fluoride analysis?

    menjawab: Total Ionic Strength Adjustment Buffer TISAB II is a specially formulated solution designed to stabilize the ionic strength and pH during fluoride analysis. It ensures the accuracy of ion selective electrodes by preventing interference from other ionic species in the sample. For instance, in environmental testing of water for fluoride levels, using TISAB II allows for precise measurements that align with regulatory standards, making it essential for laboratories dealing with water quality assessment.
  • pertanyaan: What does CDTA in TISAB II stand for?

    menjawab: CDTA stands for Cyclohexyl-2,6-diethyl-2,4-pyrimidinediamine, which is included in TISAB II to combat interference from metal ions. This complexing agent effectively binds to metal cations, preventing them from distorting fluoride measurements. In practical scenarios, laboratories that face the challenge of metallic contaminants during fluoride testing can rely on TISAB II with CDTA to achieve more reliable results.
  • pertanyaan: How should TISAB II be prepared and stored for optimal use?

    menjawab: TISAB II should be stored in a cool, dry place and kept tightly sealed to prevent contamination. It is important to follow specific preparation guidelines provided by the manufacturer for achieving the ideal concentration before use. Laboratories performing regular tests can benefit from maintaining a fresh supply of TISAB II, as old solutions may deteriorate, affecting the accuracy of fluoride analysis.
  • pertanyaan: Can TISAB II be used in different types of water analysis?

    menjawab: Yes, TISAB II is versatile and can be used in various types of water analysis, including groundwater, drinking water, and wastewater. Its formulation is designed to accommodate the unique ionic challenges posed by different water sources. For example, treatment plants analyzing fluoride levels in both raw inflow and treated effluent can utilize TISAB II to ensure consistent and precise fluoride readings across samples.
  • pertanyaan: Is TISAB II compatible with all ion selective electrodes?

    menjawab: TISAB II is compatible with most ion selective electrodes designed for fluoride analysis, as it enhances their performance by providing a controlled ionic environment. However, it's essential to check the specifications of your particular electrode to confirm compatibility. Laboratories equipped with multiple electrode systems can leverage TISAB II for interchangeable use, enhancing their operational efficiency.
  • pertanyaan: What are the advantages of using TISAB II over traditional buffers?

    menjawab: TISAB II offers enhanced ionic strength adjustment and minimizes interference from other ions, unlike many traditional buffers. It helps to stabilize the pH and ionic environment crucial for accurate fluoride ion readings. Laboratories focusing on quality control and environmental monitoring can gain a significant edge by using TISAB II, as it ensures that they meet the necessary analytical standards.
  • pertanyaan: How is TISAB II disposed of after use?

    menjawab: The disposal of TISAB II should be conducted in compliance with local regulations regarding chemical waste disposal. It's essential to check safety data sheets (SDS) provided by manufacturers for specific disposal guidelines. Laboratories can incorporate proper disposal methods in their standard operating procedures to ensure environmental responsibility while handling chemical waste.
  • pertanyaan: What precautions should be taken when handling TISAB II?

    menjawab: When handling TISAB II, it is advisable to use gloves and safety goggles to prevent skin and eye irritation. Always work in a well-ventilated area to minimize inhalation of vapors. Research and laboratory personnel who frequently use TISAB II in analyses should undergo proper training on handling hazardous materials to ensure safety and compliance with best practices.
  • pertanyaan: Is TISAB II suitable for field testing applications?

    menjawab: While TISAB II is primarily used in laboratory settings, it can be employed for field testing when immediate results are necessary. Its compact and easily transportable nature allows field researchers to conduct fluoride analysis on-site effectively. For environmental assessments where swift decision-making is crucial, TISAB II serves as an ideal solution to complement portable ion selective electrodes.
  • pertanyaan: Where can I buy Total Ionic Strength Adjustment Buffer TISAB II, with CDTA for Fluoride Analysis Using Ion Selective Electrodes in Indonesia?

    menjawab: You can buy Total Ionic Strength Adjustment Buffer TISAB II with CDTA for Fluoride Analysis Using Ion Selective Electrodes on Ubuy. This platform offers a variety of laboratory supplies, making it easier for you to find the specific buffers needed for accurate fluoride testing. Ubuy provides convenient options for exploring and acquiring necessary laboratory materials for your analysis needs.

Ricca Chemical Electrodes Editorial Review

Ulasan editorial tidak ditemukan

Customer Reviews & Ratings

5.0
1 peringkat pelanggan
  • 5 bintang
    100%
  • 4 bintang
    0%
  • 3 bintang
    0%
  • 2 bintang
    0%
  • 1 bintang
    0%

Ulas produk ini

Bagikan pikiran Anda kepada pelanggan lain

Platform Trust & Buyer Confidence

trustpilot logo
4.2/5 9250 + reviews
Read reviews
MA
Mohammad
Verified buyer

“Excellent quality and original too,when ubuy send original things I will appreciate that ,I very satisfied thank you”

23 July 2026 · via Trustpilot
CK
Chitra
Verified buyer

“The order and delivery progress was communicated very well. Package arrived within the estimated time. Products arrived as expected in good condition.”

22-Jul-26 · via Trustpilot
K
kund
Verified buyer

“Good supply of products. Safe payment methods, and shipment worldwide! Genuine products.”

23-Jul-26 · via Trustpilot
OO
Onesi
Verified buyer

“Was my first time buying a product from Ubuy, but I found it so helpful. This is reliable. Gonna place a new order!”

22 July 2026 · via Trustpilot
SJ
SAO JOHN
Verified buyer

“Ubuy is a great online platform to buy stuff. Reliable, fast delivery time and great value for money. I've been using Ubuy online shopping platform for three years now and will continue to do so.”

23 July 2026 · via Trustpilot
Pembayaran Aman Global Delivery Easy Returns Genuine Products

Product Price History

Informasi penting

  • Batasan : Untuk produk yang dikirim secara internasional, harap diperhatikan bahwa garansi pabrik mungkin tidak berlaku; pilihan layanan pabrikan mungkin tidak tersedia; manual produk, instruksi, dan peringatan keselamatan mungkin tidak tersedia dalam bahasa negara tujuan; produk (dan material penyerta) mungkin tidak dirancang sesuai standar, spesifikasi, dan persyaratan pelabelan negara tujuan; dan produk mungkin tidak sesuai dengan voltase negara tujuan dan standar kelistrikan lainnya (memerlukan penggunaan adaptor atau konverter jika tersedia). Penerima bertanggung jawab untuk memastikan bahwa produk tersebut dapat diimpor secara sah ke negara tujuan. Saat memesan dari Ubuy atau afiliasinya, penerima tercatat sebagai importir dan harus mematuhi semua hukum dan peraturan negara tujuan.
  • Tidak semua produk yang terdaftar di Ubuy sedang dijual, karena Ubuy adalah mesin pencari global. Produk tunduk pada peraturan ekspor/perdagangan.